Agilent 1260 DAD VL+ G1315C - Tested and working perfectly
$ 4646.39
- Description
- Size Guide
Description
Agilent 1260 HPLC G1315C Diode Array DetectorThe Agilent 1260 G1315C Diode Array Detector allows you to add spectral
acquisition to your HPLC analyses. The detector can verify separation
quality with peak purity, multiple signals and spectral libraries, both
interactively or automatically in the same run as your analytical
quantification. The 1260 DAD offers an extended wavelength range from
190 to 950 nm with the highest sensitivity or spectral resolution with
programmable slit, along with holmium oxide wavelength verification for
GLP compliance. The temperature management system ensures optimum
baseline stability, even under rough ambient conditions. Two lamps in
the Agilent 1260 Series diode-array detector ensure the highest light
output for the lowest detection limits over the entire wavelength range.
The use of 1,024 diodes and an optical slit programmable from 1 to 16
nm ensures the best possible spectral bandwidth.
All of our
equipment is fully tested to perform at factory specifications before
being shipped. All tests were performed using Agilent Lab-Advisor.
Tests are available upon request.
Included with the Agilent 1260 HPLC G1315C DAD Detector:
G1315 and cable
HP Agilent 1260 HPLC G1315C Diode Array Detector Specifications
Type
Specification
Detection type
1024-element photodiode array
Light Source
Deuterium and tungsten lamps
Wavelength range
190 – 950 nm
Short term noise (ASTM) single and multi-Wavelength
± 1 × 10-5 AU at 254 and 750 nm
Drift
2 × 10-3 AU/hr at 254 nm
Linear absorbance
range
> 2 AU (upper limit)
Wavelength Accuracy
± 1 nm
Wavelength bunching
1 – 400 nm
Slit width
1, 2, 4, 8, 16 nm
Diode Width
< 1 nm
Available Flow Cells (only one included with the system - Semi-Mico)
Standard:
13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure
maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760
psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path
length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume,
10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data evaluation
Agilent ChemStation for LC
Analog outputs
Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications
Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintainence
Extensive
diagnostics, error detection and display (through control module and
ChemStation), leak detection, safe leak handling, leak output signal for
shutdown of pumping system. Low voltages in major maintenance areas
GLP features
Early
maintenance feedback (EMF) for continuous tracking of instrument usage
in terms of lamp burn time with user-settable limits and feedback
messages. Electronic records of maintenance and errors. Verification of
wavelength accuracy with built-in holmium oxide filter.
Housing
All materials recyclable