-40%

Agilent G1315A 1100 Diode Array Detector - Tested and Excellent Condition

$ 1980

Availability: 100 in stock

Description

HP Agilent 1100 HPLC G1315A Diode Array Detector
The HP Agilent 1100 G1315A Diode Array Detector allows you to add spectral acquisition to your HPLC analyses. The detector can verify separation quality with peak purity, multiple signals and spectral libraries, both interactively or automatically in the same run as your analytical quantification. The 1100 DAD offers an extended wavelength range from 190 to 950 nm with the highest sensitivity or spectral resolution with programmable slit, along with holmium oxide wavelength verification for GLP compliance. The temperature management system ensures optimum baseline stability, even under rough ambient conditions. Two lamps in the Agilent 1100 Series diode-array detector ensure the highest light output for the lowest detection limits over the entire wavelength range. The use of 1,024 diodes and an optical slit programmable from 1 to 16 nm ensures the best possible spectral bandwidth.
All of our equipment is fully tested to perform at factory specifications before being shipped.  All tests were performed using Agilent Lab-Advisor.  Tests are available upon request.
Included with the HP Agilent 1100 HPLC G1315A DAD Detector:
G1315 and cable
HP Agilent 1100 HPLC G1315A Diode Array Detector Specifications
Type
Specification
Detection type
1024-element photodiode array
Light Source
Deuterium and tungsten lamps
Wavelength range
190 – 950 nm
Short term noise (ASTM) single and multi-Wavelength
± 1 × 10-5 AU at 254 and 750 nm
Drift
2 × 10-3 AU/hr at 254 nm
Linear absorbance
range
> 2 AU (upper limit)
Wavelength Accuracy
± 1 nm
Wavelength bunching
1 – 400 nm
Slit width
1, 2, 4, 8, 16 nm
Diode Width
< 1 nm
Available Flow Cells (only one included with the system - Semi-Mico)
Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum
Control and data evaluation
Agilent ChemStation for LC
Analog outputs
Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs
Communications
Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Safety and maintainence
Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas
GLP features
Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter.
Housing
All materials recyclable